Browse all practice questions for the Electric Vehicle Infrastructure Training Program (EVITP) Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Electric Vehicle Infrastructure Training Program (EVITP) Practice Test course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • What is the practical difference between a hardwired EVSE and a receptacle-based EVSE?
  • DC charging equipment provides DC directly to which component in an EV?
  • When would a DCFC installation typically require a utility interconnection or interconnection agreement?
  • Charging is defined as which of the following?
  • What information is typically indicated by labeling regarding connectors on DC fast charging stations?
  • NEC Chapters 1-4 apply to which installations?
  • In EVSE installations, how do you distinguish between a feeder and a branch circuit?
  • Which sequence correctly describes how to verify conductor ampacity for an EVSE feeder under NEC guidelines?
  • How can load management and storage help when a site cannot support full EVSE deployment?
  • How is fault isolation performed on an EV charging circuit?
  • Labeling information on an EVSE installation should provide which of the following?
  • Conducting an onsite visit when assessing a location for EVSE installation is important for which of the following reasons?
  • Why is metering important at EV charging sites, and what forms can it take?
  • Wireless charging is more expensive than coupled EVSE.
  • How do environmental exposure considerations affect EVSE cable and connector design?
  • Electric vehicle supply equipment (EVSE) provides which of the following safety features?
  • Which section of the flowchart outlines issues specific to testing and procedures and may be used as a sequence of events?
  • Which factor might trigger a service upgrade when adding multiple EV chargers?
  • How does ambient temperature affect conductor ampacity and how is this accounted for in EVSE design?
  • What is the maximum length for an EVSE output cable?
  • Which DC fast charging standard is most common in the U.S., and what other standard is still used in some stations?
  • What is the main purpose of commissioning in building systems?
  • The control pilot signal in the J1772 system uses which type of signal?
  • In branch circuit receptacle load calculations, the load is the larger of which two values?
  • Which describes an EV drivetrain architecture in which power can be transmitted to the drive from two sources at the same time?
  • Which of the following are identified by the tables in Article 310?
  • What site planning considerations improve accessibility and safety at EV charging installations?
  • How should a project ensure compliance when adding multiple EVSEs to an existing electrical service?
  • How many new EVSEs can be added to a 600 A service with 220 A non-continuous and 172 A continuous, given each EVSE draws 32 A, using three-phase calculations?
  • What is the function of a grounding electrode system (GES) at EV charging sites, and how should it be bonded?
  • ADA guidelines are useful when planning an EVSE installation because?
  • In the EVSE repair process, which step immediately precedes disassembly?
  • What is the primary purpose of interconnection requirements in DC fast charging installations?
  • What role does metering play in DC fast charging installations?
  • Which incentives are available for EVSE installation?
  • Installations covered by the NEC include which of the following?
  • Determining the appropriate location for EVSE requires considering which factors?
  • Which category of EV has been available to consumers the longest?
  • In high‑voltage training for EV charging, what equipment is typically required for protection?
  • GFCI protection is typically required for which locations or circuits?
  • Fleet vehicle battery capacity has reached upward of ? for heavy duty vehicles.
  • How does NEC require continuous loads to be treated for conductor and OCPD sizing in EV installations?
  • Which of the following is not true of EV charging networks?
  • Which statement correctly describes whether connector configuration affects charging time?
  • What types of commercial/industrial vehicles are currently available in an electrified version?
  • PZEV stands for Partial Zero Emission Vehicle.
  • The CHAdeMO V1.0 Standard allows charging up to which power, voltage, and current?
  • At 220 VAC, Level 2 EVSE rated 6.6 kilowatts can supply how much charge current?
  • How should you test the vehicle-to-charger communication after installation?
  • What is the role of the control pilot (CP) line in EV charging systems?
  • Two Level II EVSE circuits installed in the same PVC conduit. Each EVSE is served by a 40-ampere circuit at 240 volts with an EGC run along with the circuits. What size copper EGC is required for this installation?
  • The first electric vehicle can be traced back to which year?
  • Which source is used to determine conductor ampacity for EVSE feeders under NEC guidelines?
  • What is the purpose of backfeed protection in interconnection requirements?
  • What does EVSE stand for?
  • When an EV and EVSE are used to facilitate power supply as an interactive power production source, which article must be applied?
  • Which set of issues and mitigations correctly matches common failure modes in EV charging infrastructure?
  • What is the purpose of as-built drawings in EVSE installations?
  • Bonding conductors connect the EVSE ground to which elements?
  • Which of the following best describes a common safety concern associated with EVSE cords?
  • According to ADA guidelines, what percentage of general parking spaces should be accessible?
  • How should conductors be protected when installed outdoors or in areas with physical risk?
  • An AC charger with a single-phase 120-volt connection and 14-16 amperes of continuous current output is classified as a ? charger.
  • Installing EVSE at an existing building can earn up to how many LEED points?
  • Which NEC article specifically governs EV charging equipment installation?
  • Adequate site lighting increases the safety of an EVSE location.
  • The EV's power acceptance rate should not be considered when making EVSE purchasing decisions.
  • Which improvements in technology increased interest in EVs?
  • Which article contains calculation methods for determining conductor ampacity?
  • In the EVSE repair sequence, which step follows inspection for damage?
  • What was the first mass-produced hybrid electric vehicle?
  • What is the impact of adding EV charging on feeders and transformers in a commercial area?
  • Installing electric vehicle charging equipment may affect public perception of a business by
  • Why is utility coordination important for EV charging projects, particularly DCFC?
  • What does NEC stand for?
  • Installing EVSE in an existing building can contribute up to how many LEED points?
  • What is a typical sequence for commissioning an EV charging installation?
  • In the EVSE repair sequence, which step follows disassembly?
  • What is the purpose of multiplying the EVSE rating by 1.25 when sizing the circuit?
  • Which set of items is typically included in the hand-off documentation for EVSE projects?
  • What is the maximum voltage drop recommended for branch circuits and feeders/electrical systems in the National Electrical Code (NEC)?
  • Recognized types of EVCE activation technology include which of the following?
  • Which drivetrain configuration uses two sources for propulsion, allowing power to be delivered by both sources simultaneously?
  • What is the final step after completing repairs and verification?
  • In a maintenance program, which statement best describes ongoing maintenance tasks?
  • Which statement about EV networks revenue is true?
  • Regenerative braking converts kinetic energy into electrical energy to be stored in the battery.
  • The statement that NECA 413-2012 requirements are described as performance-based is true.
  • What is the purpose of lockout/tagout procedures during maintenance?
  • Level 1 charging is defined by which supply characteristics?
  • Part of the initial setup of fleet EVSE is making sure that the customer is comfortable with ?
  • The purpose of the J1772 connector pins is to provide which of the following?
  • Operable parts of accessible equipment should be located how far above finish grade per ADA guidelines?
  • What is the primary function of the equipment grounding conductor in EV charging installations?
  • The acronym RFID stands for ?
  • Which statement best describes the application of NEC Chapters 1-4?
  • How are emergency shutdowns typically implemented in EV charging stations?
  • True or False: The maximum amount of current a conductor can carry under the conditions of use without exceeding its temperature rating is found using calculation methods based in Article 310.
  • Minimum copper THHN feeder size for 12 EVSEs rated at 24 amperes on a 3-phase, 4-wire, 120/208-volt system, assuming four EVSE per phase? (Use 1.732 for the square root of 3.)
  • Which vehicle is widely recognized as the first mass-produced hybrid electric vehicle?
  • What is the difference between a "control-ready" EVSE and one that only uses vehicle-side control?
  • What is the role of the control pilot (CP) line in J1772 charging?
  • What best describes early EVs?
  • PZEV stands for which of the following?
  • A Level II EVSE with a rating of 32 amperes at 208 volts is installed. What is the minimum size copper equipment grounding conductor required to serve the installation?
  • Which enclosure ratings are appropriate for outdoor EVSE equipment?
  • EVSE stands for what?
  • During a site visit for an EVSE installation, which information should be gathered?
  • In ADA guidelines for EVSE planning, which of the following statements is true?
  • Regenerative braking is best described by which of the following?
  • What thermal management considerations are critical for DC fast charging stations?
  • A 32,000 square foot office building has 120 20-ampere, 120-volt duplex receptacle outlets. What is the branch circuit receptacle load?
  • What is the purpose of the documentation step in the EVSE commissioning sequence?
  • An existing 400 A, 120/208-volt, 3-phase, 4-wire service has 30 kilovolt-amperes of non-continuous load and 58 kilovolt-amperes of continuous load. How much more continuous load can be added to the service?
  • How do protection barriers help in EV charging installations?
  • What labeling and safety signage is typically required for DC fast charging stations?
  • Minimum branch circuit size for Level II EVSE with 32-ampere rating?
  • Which of the following is true about the J1772 standard control pilot terminal pin's function?
  • Additional EVSEs are to be added to an existing 120/208-volt, 3-phase, 4-wire, 600-ampere service with 220 amperes of non-continuous load and 172 amperes of continuous load. The EVSEs each draw 32 amperes. How many new EVSEs can be added to the service?
  • How are cables and connectors rated to handle high currents during DC fast charging?
  • Why is weatherproofing important for EVSE connectors and enclosures installed outdoors?
  • Which safety standards form the foundation for EVITP safety training on the jobsite?
  • Labeling should typically include which item as part of EVSE installation information?
  • What is a demand response program in the context of EV charging?
  • What is the purpose of lockout/tagout (LOTO) in EV charging work?
  • Level 2 AC charging in North America is typically characterized by which voltage and current range?
  • Which standard covers planning an EVSE installation, including ADA considerations and commissioning?
  • What does grid impact refer to in the context of EV charging projects?
  • In EV charging circuits, what is the role of overcurrent protection devices (OCPD)?
  • Why are pre-approval or inspections important for EV charging installs?
  • Compared to Level 1 and Level 2 EVSE, DC fast chargers typically have cables and connectors that are?
  • How do single-phase 120/240 V charging and three-phase charging compare in terms of power delivery?
  • Is the following statement true? DC fast chargers pose accessibility challenges because their cables and connectors are larger and heavier than standard Level 1 and Level 2 EVSE.
  • What is the primary reason for proper grounding and bonding in outdoor EV charging installations?
  • Protection requirements for branch circuits and AFCI/GFCI protection are found in which NEC article?
  • What are typical EVITP training requirements for installers?
  • Which statement about early electric vehicles is correct?
  • How can an energy management system reduce utility demand charges at an EV charging site?
  • Which statement best explains why electric vehicles were popular in the early days of automobiles?
  • During the EVSE commissioning sequence, which step directly verifies that the control pilot (CP) communication works between the EVSE and the vehicle?
  • During EVSE repair, which step involves evaluating all components for damage?
  • At 240 V and 80 A, approximately how many kilowatts does Level 2 charging deliver?
  • What is the Japanese DC quick charging standard?
  • Which of the following is not a category of electric vehicles?
  • Which statement best describes the function of a rectifier in electric vehicle charging?
  • Which unit describes the capacity of heavy-duty fleet EV batteries?
  • Which improvements most contributed to greater EV appeal by addressing battery and range limitations?
  • Which of the following is not an alternative to fossil fuels?
  • What is the final step in the troubleshooting and repair guidelines flowchart?
  • EVSE shall have a(n) ? system for shock protection for personnel.
  • Problems with data servers, EVSE locator networks, and billing networks are typically caused by what type of problem?
  • Which statement about site lighting and safety for EVSE locations is true?
  • The first electric vehicle can be traced back to which year?
  • What does GFCI protection do, and where is it typically required on EV charging equipment?
  • What is the purpose of a dedicated disconnect for EVSE during maintenance?
  • What is the process that ensures mechanical, electrical, and other building systems are installed, tested, and perform interactively in accordance with design documents?
  • The first EV chargers were external and supplied DC current directly to the vehicle's batteries.
  • Cord management is a major concern for manufacturers of EVSE because charge cables can cause a tripping hazard and are often subject to theft. True or False?
  • What type of test results should be included in EVSE maintenance documentation?
  • The proper hand-off of documentation should include electrical details, contract documents, operation and maintenance manuals as well as ?
  • Overcurrent protection for EVSE is covered in which section?
  • What is the role of weatherproof enclosures in outdoor EVSE installations?
  • A plug-in electric vehicle that runs on batteries until nearly depleted and then uses an internal combustion engine to extend the battery range is classified as what?
  • Which option indicates the final release of the EVSE when it is fully operational?
  • In repairing an EVSE unit, which action should occur first?
  • Which step involves beginning repairs or replacement after inspection?
  • What factors limited the adoption of EVs in the early 1900s?
  • Why is cable strain relief important at the point of connection?
  • The most commonly reported repair to electric vehicle supply equipment (EVSE) manufacturers is damage to the ?
  • Which statement about public perception of a business after EVSE installation is true?
  • EVSE output cable is permitted to be made from which Type, and it has a maximum length of which?
  • Which factors should be considered when determining EVSE location?
  • Which of the following is not a variable that determines the charging time of an EV?
  • Commercial and fleet EVSE installations often require ? communications and ? functions.
  • When an EV and its EVSE is used as a power supply for an optional standby system, requirements are found in which article?
  • Why is insulation resistance testing performed during commissioning?
  • The NECA 413-2012 Standard is the only ANSI-approved standard for EVSE installation and maintenance.
  • Which statement about the state of charge is correct?
  • Which cable type is explicitly identified as permissible for EVSE output cables?
  • The NEC provides minimum installation requirements.
  • EVSE provides DC power to the electric vehicle charging port.
  • Which of the following was an early electric vehicle charger?
  • For a Level II EVSE rated 32 amperes, what is the minimum overcurrent protective device size required by NEC 250.122?
  • What is the primary purpose of a junction box in EV charging installations?
  • Charging methods for battery electric buses include which of the following?
  • Definitions that are specific to a particular article are located in which of the following sections?
  • Which statement best describes charging methods for battery electric vehicles?
  • Which statement describes the Level 2 charging power capability when using a 208–240 V supply up to 80 A?
  • Which factors limited the popularity of EVs as internal combustion engine vehicles came to the market in the early 1900s?
  • Utilities or municipalities may have requirements that ?
  • Which action is used to verify the EVSE unit after repairs and before commissioning?
  • Which of the following describes the scope of the NEC?
  • According to Article 625, EVSE transfers energy from which to the electric vehicle?
  • EV networks generate revenue with which of the following?
  • How does EVITP define high‑voltage systems, and what are the implications for training?
  • Which ongoing maintenance practice helps ensure EVSE reliability?
  • What environmental hazards must be considered for outdoor EVSE installations, and how are they mitigated?
  • Why are torque checks important in EV charging infrastructure maintenance?
  • In the repair sequence, which step comes immediately after locking out the EVSE?
  • Which describes a plug-in electric vehicle that runs on batteries until nearly depleted, then switches over to an ICE generator to extend the battery range?
  • Which article addresses energy transfer equipment used in EV charging installations?
  • How many certification levels does LEED have?
  • Later in the development of EV charging equipment, the actual charging means was accomplished by a device that converts AC to DC to be used in charging the vehicle's battery.
  • In three-phase calculations, what factor is used to convert line current to feeder current?
  • What distinguishes a 'smart charger' from a non-smart charger?
  • What documentation should be retained for EVSE installations to support maintenance and inspections?
  • Which of the following outlines the steps, in order, for repairing an EVSE unit?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy